FBC Boiler and Installation Fluidised Bed Combustion Boilers

FBC Boiler and Installation Fluidised Bed Combustion Boilers

  • Water Quality Parameters | IntechOpen

    2019/3/2 · The measurement of alkalinity of water is necessary to determine the amount of lime and soda needed for water softening (e.g., for corrosion control in conditioning the boiler feed water) []. Alkalinity of water is mainly caused by the presence of hydroxide ions (OH − ), bicarbonate ions (HCO 3− ), and carbonate ions (CO 3 2− ), or a mixture of two of these ions …Get Price

  • Discover the On-line Analyzers Suite on .applitek

    EnviroLyzer® Chlorine (free) Chlorine is an oxidizing agent acting as a biocide in various types of water and in particular to avoid biofouling in boiler and cooling water systems. Free Cl 2 levels are determined by means of the DPD colorimetric analysis method (NGet Price

  • How can I measure chloride ion concentration in boiler water in …

    Many times boiler water becomes contaminated with chloride ions due to condenser tube leakage. Can it be measured with a nephelometer or turbidity meter by …Get Price

  • Document Center, Inc. | Your Online Library of US and International Standards

    ASTM-D807 - Standard Practice for Assessing the Tendency of Industrial Boiler Waters to Cause Embrittlement (UKefid Embrittlement Detector Method) ASTM-D8234 - Standard Test Method for Anions in High Ionic Water by Ion Chromatography using TandemGet Price

  • Boiler Water System and Treatment - MirMarine

    Chloride content: Chloride content determines the level of chloride salt in the boiler water, which may be due to ingress of seawater or impure water (shore water). Chloride ions, unlike other ions that enter the boiler, are extremely soluble and do not precipitate or decompose when subjected to boiler conditions.Get Price

  • Boiler Feedwater Treatment (Part I): Why Water Treatment is Necessary …

    It measures the sodium ion content in a cooled steam sample that will correspond to the amount of boiler water solids contaminating the steam. The sodium ion analyzer can detect carryover down to 1 ppb sodium in steam.Get Price

  • Water Handbook - Measurement of Steam Purity | SUEZ

    When boiler water is carried over in steam, the dissolved solids content of the boiler water contaminates the steam, and steam sample conductivity increases. Measurement of this increase provides a rapid and reasonably accurate method for determining steam purity.Get Price

  • BASIC WATER TREATMENT OF STEAM BOILERS

    2000/5/2 · Chlorides, however, are relatively unaffected by other materials in the boiler. When compared to the makeup water chloride concentration, boiler water chloride concentration will most accurately show the cycles of concentration of a boiler. Consequently, chloridesGet Price

  • CN102621135A - Method for detecting trace chloride ions in …

    The invention relates to a chloride ion detecting method, in particular to a method for detecting trace chloride ions in boiler water, which overcomes the defects in the prior art and is novel, free of expensive instruments, simple in operation and capable of accurately Get Price

  • Measurement of organic halogens in boiler

    caused by chloride, are important causes of boiler and turbine deterioration, so demineralized boiler feedwater has to meet stringent water quality demand. Oxygen, low pH and anions in BFW can lead to the corrosion. Corrosion from halide ions including fluorideGet Price

  • (PDF) BASIC WATER TREATMENT OF STEAM BOILERS | …

    As the boiler is filled, the drum collects the overflow. Then, as a vacuum develops because of cooling, the water in the drum enters the boiler and keeps it full. Additional water added to keep the drum filled should be treated with sulfite (1 oz per 50 gallons) and caustic (approximately 1.5 oz per 50 gallons). 7.Get Price

  • Water Handbook - Analytical Methods And Equipment | SUEZ

    Ion Chromatography is used to measure trace levels of anions in feedwater, steam, condensate, and boiler water. Atomic Absorption Spectroscopy (AA), Inductively Coupled Ion Spectroscopy (ICP), X-ray Fluorescence Spectroscopy, and other laboratory procedures are used routinely to measure many elements at trace levels in a fraction of the time required for wet chemical …Get Price